為落實 “水十條”等國家政策要求,提升污水處理效能,改善水環(huán)境質(zhì)量,我國重點流域區(qū)域已陸續(xù)制定高于《城鎮(zhèn)污水處理廠污染物排放標準》(GB 18918—2002)一級A標準的主要污染物地方排放限值。經(jīng)大規(guī)模系統(tǒng)調(diào)研分析,共性難點為如何有效摸清本底,識別現(xiàn)狀問題,形成技術(shù)可行、經(jīng)濟合理的技術(shù)對策。系統(tǒng)構(gòu)建了“四位一體”精準診斷技術(shù)方法,涵蓋“問題初篩—難點解析—系統(tǒng)診斷—應用驗證”四個緊密銜接、前后依托的診斷步驟,系統(tǒng)提出各步驟的重點目標及實施方案,以常州江邊污水處理廠三期為例進行了系統(tǒng)應用說明。該技術(shù)方法已收錄于江蘇、廣東等地發(fā)布的提標政策指導文件,為我國城鎮(zhèn)污水處理系統(tǒng)提標建設(shè)及精細化運行管理提供了系統(tǒng)技術(shù)支撐。
In order to implement the national policy requirements such as Water Pollution Control Action Plan, enhance the sewage treatment efficiency and improve the water environment quality, the local discharge limits of major pollutants in key basins and region of China have been formulated one after another, which are all higher than that of the first class A standard of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002). Through large-scale systematic investigation and analysis, the common difficulties of upgrading include how to find out the background effectively, identify the current situation, and put forward the technically feasible and economically reasonable countermeasures. In this paper, the “four in one” accurate diagnosis technology method is systematically constructed, covering the four closely connected and back-to-back operation steps of “problem preliminary screening-difficulty analysis-system diagnosis-application verification”, the key objectives and implementation plan of each step are put forward systematically, and the system application of the systematic and accurate diagnosis technology in Changzhou Jiangbian WWTP is introduced. The technical method has been included in the upgrading policy guidance documents issued by Jiangsu, Guangdong and other provinces, which provides systematic technical support for the upgrading construction and refined operation management of urban wastewater treatment system in China.
[1]李鵬峰,鄭興燦,孫永利,等.城鎮(zhèn)污水處理廠系統(tǒng)化精準診斷技術(shù)方法構(gòu)建及應用[J].中國給水排水,2021,37(12):1-6.
LI Peng-feng,ZHENG Xing-can,SUN Yong-li,et al.Construction and Application of Systematic and Accurate Diagnosis Technology for Urban WWTP[J].China Water & Wastewater,2021,37(12):1-6.
LI Peng-feng,ZHENG Xing-can,SUN Yong-li,et al.Construction and Application of Systematic and Accurate Diagnosis Technology for Urban WWTP[J].China Water & Wastewater,2021,37(12):1-6.
點擊復制
城鎮(zhèn)污水處理廠系統(tǒng)化精準診斷技術(shù)方法構(gòu)建及應用
中國給水排水[ISSN:1000-4062/CN:12-1073/TU] 卷: 第37卷 期數(shù): 2021年第12期 頁碼: 1-6 欄目: 出版日期: 2021-06-17
- Title:
- Construction and Application of Systematic and Accurate Diagnosis Technology for Urban WWTP
關(guān)鍵詞:
城鎮(zhèn)污水處理廠; 提標建設(shè); 精準診斷
- Keywords:
- urban WWTP; upgrading construction; accurate diagnosis
摘要:
為落實 “水十條”等國家政策要求,提升污水處理效能,改善水環(huán)境質(zhì)量,我國重點流域區(qū)域已陸續(xù)制定高于《城鎮(zhèn)污水處理廠污染物排放標準》(GB 18918—2002)一級A標準的主要污染物地方排放限值。經(jīng)大規(guī)模系統(tǒng)調(diào)研分析,共性難點為如何有效摸清本底,識別現(xiàn)狀問題,形成技術(shù)可行、經(jīng)濟合理的技術(shù)對策。系統(tǒng)構(gòu)建了“四位一體”精準診斷技術(shù)方法,涵蓋“問題初篩—難點解析—系統(tǒng)診斷—應用驗證”四個緊密銜接、前后依托的診斷步驟,系統(tǒng)提出各步驟的重點目標及實施方案,以常州江邊污水處理廠三期為例進行了系統(tǒng)應用說明。該技術(shù)方法已收錄于江蘇、廣東等地發(fā)布的提標政策指導文件,為我國城鎮(zhèn)污水處理系統(tǒng)提標建設(shè)及精細化運行管理提供了系統(tǒng)技術(shù)支撐。
- Abstract:
- In order to implement the national policy requirements such as Water Pollution Control Action Plan, enhance the sewage treatment efficiency and improve the water environment quality, the local discharge limits of major pollutants in key basins and region of China have been formulated one after another, which are all higher than that of the first class A standard of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002). Through large-scale systematic investigation and analysis, the common difficulties of upgrading include how to find out the background effectively, identify the current situation, and put forward the technically feasible and economically reasonable countermeasures. In this paper, the “four in one” accurate diagnosis technology method is systematically constructed, covering the four closely connected and back-to-back operation steps of “problem preliminary screening-difficulty analysis-system diagnosis-application verification”, the key objectives and implementation plan of each step are put forward systematically, and the system application of the systematic and accurate diagnosis technology in Changzhou Jiangbian WWTP is introduced. The technical method has been included in the upgrading policy guidance documents issued by Jiangsu, Guangdong and other provinces, which provides systematic technical support for the upgrading construction and refined operation management of urban wastewater treatment system in China.
近期發(fā)表
近期發(fā)表
10:40
已群發(fā)
16
1
1
昨天 11:57
已群發(fā)
187
1
1
星期一 16:04
已群發(fā)
117
1
1
星期日 19:04
已群發(fā)
294
1
1
星期六 21:28
群發(fā)失敗
星期六 00:00
已群發(fā)
160
1
2
星期五 12:15
已群發(fā)
202
1
1
星期四 11:59
已群發(fā)
183
1
1
11月17日
已群發(fā)
149
2
1
11月16日
已群發(fā)
423
2
1
10:40
已群發(fā)
16
1
1
昨天 11:57
已群發(fā)
187
1
1
星期一 16:04
已群發(fā)
117
1
1
星期日 19:04
已群發(fā)
294
1
1
星期六 21:28
群發(fā)失敗
星期六 00:00
已群發(fā)
160
1
2
星期五 12:15
已群發(fā)
202
1
1
星期四 11:59
已群發(fā)
183
1
1
11月17日
已群發(fā)
149
2
1
11月16日
已群發(fā)
423
2
1
近期發(fā)表
相似文獻/References:
[1]王慕,談?wù)駤?李激,等.城鎮(zhèn)污水處理廠次氯酸鈉消毒效果的影響因素研究[J].中國給水排水,2021,37(1):22.
WANG Mu,TAN Zhen-jiao,LI Ji,et al.Influence Factors of Sodium Hypochlorite Disinfection Performance in Municipal Wastewater Treatment Plant[J].China Water & Wastewater,2021,37(12):22.